Home
Services
Services – Children
Sectors
Sectors – Children
Products
Products – Children

Portfolio
Portfolio – Children
About Us
About Us – Children
Blog
Blog – Children
Contact Us
Privacy and Cookies

Model 6500 Friction Flow Loop System

Model 6500 Friction Flow Loop System

The Chandler Engineering 6500 Friction Flow Loop is a fully automated system which includes the necessary hardware and software to measure the friction pressure of different fluids. It can, therefore, be used to determine the effects of friction reducers on fluids over a wide range of pressures and flow rate conditions and through different pipe diameters.

Friction Flow Loop System

The 6500 Friction Flow Loop system circulates fluid through two test sections of various diameters in order to generate differential pressure versus flow rate data. This data helps to determine the effectiveness and longevity of various friction reducing agents added to the test fluids.

The system incorporates a low shear, progressive cavity pump for injection of base fluids with the flow rate controlled by a Coriolis flow meter. Differential pressure transducers are provided on each tube diameter, allowing for multiple data readings per test. Fluid can be injected into the flow stream via an optional metering pump or added directly into a 55 litre reservoir mixing tank.

The software is designed for ease of use and is powerful enough to calculate and collect all required data during the test cycle. The software gives the operator total control over the flow rate, test time and temperature (optional) of each individual test. A .CSV file for analysis is created which stores all the data and test parameters.

Interested? Get in touch with us here or call +44 (0)1932 732340 and we will be happy to help answer your questions and provide you with further information.

Features

  • Open or Closed Loop Architecture
  • Easy to Set-Up, Operate, Clean, Maintain and Calibrate
    – Flush-and-Fill automation for easy system cleanup
  • Wall or Floor Mountable
  • ½” and ¾” O.D., 25’ length tubing sections (10’ test sections)
  • Coriolis Mass Flow Meter
    – Accurate measurement and feedback of flow rate
  • Over Pressure Relief Valve
    – Safety Control – Prevents operation above the designed pressures
  • Progressive Cavity Style Pump
    – Provides very low shear to fluids during injection
  • Real Time Display of Reynolds Number, Flow Rate, Temperature, Differential Pressure

Maximum Pressure: 150 PSI (250 PSI Optional)
Flow Rate Range: 2 – 15 Gallons / Minute
Fluid Temperature Range: 60 – 90°F (40°F with Optional Chiller)
Differential Pressure Range (1): 0 – 30 PSI
Differential Pressure Range (2): 0 – 100 PSI
Differential Pressure Accuracy: 0.1% of Full Range

Utilities

Power Requirements: 208 – 240 VAC, 50 or 60 Hz, 40A
Dimensions (w x d x h): 30’ x 4’ x 6’
Compressed Air: 80-120 psi
Water: 20-30 psi (for system cleanup)